Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 12(12): e0189937, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29261791

RESUMO

Cooling towers (CTs) are a leading source of outbreaks of Legionnaires' disease (LD), a severe form of pneumonia caused by inhalation of aerosols containing Legionella bacteria. Accordingly, proper maintenance of CTs is vital for the prevention of LD. The aim of this study was to determine the distribution of Legionella in a subset of regionally diverse US CTs and characterize the associated microbial communities. Between July and September of 2016, we obtained aliquots from water samples collected for routine Legionella testing from 196 CTs located in eight of the nine continental US climate regions. After screening for Legionella by PCR, positive samples were cultured and the resulting Legionella isolates were further characterized. Overall, 84% (164) were PCR-positive, including samples from every region studied. Of the PCR-positive samples, Legionella spp were isolated from 47% (78), L. pneumophila was isolated from 32% (53), and L. pneumophila serogroup 1 (Lp1) was isolated from 24% (40). Overall, 144 unique Legionella isolates were identified; 53% (76) of these were Legionella pneumophila. Of the 76 L. pneumophila isolates, 51% (39) were Lp1. Legionella were isolated from CTs in seven of the eight US regions examined. 16S rRNA amplicon sequencing was used to compare the bacterial communities of CT waters with and without detectable Legionella as well as the microbiomes of waters from different climate regions. Interestingly, the microbial communities were homogenous across climate regions. When a subset of seven CTs sampled in April and July were compared, there was no association with changes in corresponding CT microbiomes over time in the samples that became culture-positive for Legionella. Legionella species and Lp1 were detected frequently among the samples examined in this first large-scale study of Legionella in US CTs. Our findings highlight that, under the right conditions, there is the potential for CT-related LD outbreaks to occur throughout the US.


Assuntos
Legionella/fisiologia , Microbiologia da Água , Biodiversidade , Clima , DNA Bacteriano/isolamento & purificação , Geografia , Microbiota , Filogenia , Reação em Cadeia da Polimerase , Estações do Ano , Estados Unidos/epidemiologia
2.
Diagn Microbiol Infect Dis ; 85(3): 295-301, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27107536

RESUMO

Legionnaires' disease is a severe respiratory disease that is estimated to cause between 8,000 and 18,000 hospitalizations each year, though the exact burden is unknown due to under-utilization of diagnostic testing. Although Legionella pneumophila is the most common species detected in clinical cases (80-90%), other species have also been reported to cause disease. However, little is known about Legionnaires' disease caused by these non-pneumophila species. We designed a multiplex real-time PCR assay for detection of all Legionella spp. and simultaneous specific identification of four clinically-relevant Legionella species, L. anisa, L. bozemanii, L. longbeachae, and L. micdadei, using 5'-hydrolysis probe real-time PCR. The analytical sensitivity for detection of nucleic acid from each target species was ≤50fg per reaction. We demonstrated the utility of this assay in spiked human sputum specimens. This assay could serve as a tool for understanding the scope and impact of non-pneumophila Legionella species in human disease.


Assuntos
Primers do DNA/genética , Legionella/classificação , Legionella/isolamento & purificação , Doença dos Legionários/microbiologia , Reação em Cadeia da Polimerase Multiplex/métodos , Sondas de Oligonucleotídeos/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Humanos , Legionella/genética , Sensibilidade e Especificidade
3.
Clin Infect Dis ; 60(11): 1596-602, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25722201

RESUMO

BACKGROUND: Healthcare-associated Legionnaires' disease (LD) is a preventable pneumonia with a 30% case fatality rate. The Centers for Disease Control and Prevention guidelines recommend a high index of suspicion for the diagnosis of healthcare-associated LD. We characterized an outbreak and evaluated contributing factors in a hospital using copper-silver ionization for prevention of Legionella growth in water. METHODS: Through medical records review at a large, urban tertiary care hospital in November 2012, we identified patients diagnosed with LD during 2011-2012. Laboratory-confirmed cases were categorized as definite, probable, and not healthcare associated based on time spent in the hospital during the incubation period. We performed an environmental assessment of the hospital, including collection of samples for Legionella culture. Clinical and environmental isolates were compared by genotyping. Copper and silver ion concentrations were measured in 11 water samples. RESULTS: We identified 5 definite and 17 probable healthcare-associated LD cases; 6 case patients died. Of 25 locations (mostly potable water) where environmental samples were obtained for Legionella-specific culture, all but 2 showed Legionella growth; 11 isolates were identical to 3 clinical isolates by sequence-based typing. Mean copper and silver concentrations were at or above the manufacturer's recommended target for Legionella control. Despite this, all samples where copper and silver concentrations were tested showed Legionella growth. CONCLUSIONS: This outbreak was linked to the hospital's potable water system and highlights the importance of maintaining a high index of suspicion for healthcare-associated LD, even in the setting of a long-term disinfection program.


Assuntos
Infecção Hospitalar/epidemiologia , Surtos de Doenças , Desinfecção/métodos , Monitoramento Epidemiológico , Doença dos Legionários/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Infecção Hospitalar/diagnóstico , Humanos , Controle de Infecções/métodos , Doença dos Legionários/diagnóstico , Pessoa de Meia-Idade , Pennsylvania/epidemiologia , Centros de Atenção Terciária
4.
Int J Microbiol ; 2012: 218791, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22287969

RESUMO

Members of the Gram-negative genus Legionella are typically found in freshwater environments, with the exception of L. longbeachae, which is present in composts and potting mixes. When contaminated aerosols are inhaled, legionellosis may result, typically as either the more serious pneumonia Legionnaires' disease or the less severe flu-like illness Pontiac fever. It is presumed that all species of the genus Legionella are capable of causing disease in humans. As a followup to a prior clinical study of legionellosis in rural Thailand, indigenous soil samples were collected proximal to cases' homes and workplaces and tested for the presence of legionellae by culture. We obtained 115 isolates from 22/39 soil samples and used sequence-based methods to identify 12 known species of Legionella represented by 87 isolates.

5.
Int J Syst Evol Microbiol ; 62(Pt 2): 284-288, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21398499

RESUMO

A novel Legionella species was identified based on analysis of 16S rRNA and mip (macrophage infectivity potentiator) gene sequences, cellular fatty acids, isoprenoid quinones, biochemical reactions, antigens and quantitative DNA-DNA hybridization. Strain CDC-1796-JAP-E(T) was isolated from well water at the Nagasaki Municipal Medical Center, Japan. Two strains, CDC-3041-AUS-E and CDC-3558-AUS-E, were isolated from water samples during an outbreak of legionellosis in South Australia. Strain CDC-5427-OH-H was isolated from a 66-year-old female patient diagnosed with Legionnaires' disease in the US. Cells from these four strains were gram-negative, non-fluorescent, rod-shaped, and positive for alkaline phosphatase, esterase, leucine arylamidase, catalase, gelatinase, ß-lactamase and tyrosine browning assay. Phylogenetic analysis of 16S rRNA and mip genes revealed that the four strains formed a distinct cluster within the genus Legionella. The bacteria contained branched-chain fatty acids and quinones that are typical of members of the genus Legionella. Slide agglutination tests demonstrated no cross-reaction with 52 previously described members of the Legionellaceae. DNA-DNA hybridization studies indicated that DNAs from the four strains were highly related (78-84 %) but they showed 29 % relatedness to Legionella oakridgensis ATCC 33761(T) and less than 10 % to strains of other Legionella species tested. These characterizations suggest that the isolates represent a novel species, for which the name Legionella nagasakiensis sp. nov. is proposed; the type strain is CDC-1796-JAP-E(T) ( = ATCC BAA-1557(T) = JCM 15315(T)).


Assuntos
Água Doce/microbiologia , Legionella/classificação , Legionella/isolamento & purificação , Legionelose/microbiologia , Pneumonia Bacteriana/microbiologia , Abastecimento de Água , Idoso , Proteínas de Bactérias/genética , Técnicas de Tipagem Bacteriana , DNA Bacteriano/análise , DNA Ribossômico/análise , Ácidos Graxos/análise , Feminino , Genes de RNAr , Humanos , Japão/epidemiologia , Legionella/genética , Legionella/fisiologia , Dados de Sequência Molecular , Hibridização de Ácido Nucleico , Peptidilprolil Isomerase/genética , Filogenia , Quinonas/análise , RNA Ribossômico 16S/genética , Análise de Sequência de DNA , Austrália do Sul/epidemiologia , Especificidade da Espécie , Estados Unidos/epidemiologia
6.
Clin Infect Dis ; 40(8): 1205-7, 2005 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-15791524

RESUMO

We investigated 3 cases of legionnaires disease (LD) that developed in travelers who stayed at a hotel in the United States Virgin Islands where cases of LD occurred in 1981-1982 and in 1998. The temperature of the potable water at the hotel was in a range that could optimally support the growth of Legionella species, and the potable water was colonized with Legionella pneumophila in 1981-1982 and in 2002-2003.


Assuntos
Doença dos Legionários/epidemiologia , Humanos , Doença dos Legionários/microbiologia , Viagem , Ilhas Virgens Americanas/epidemiologia , Microbiologia da Água
7.
Clin Infect Dis ; 37(10): 1292-7, 2003 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-14583861

RESUMO

This case-control study investigated a cluster of respiratory illness among patrons of a restaurant. Of 173 patrons interviewed, 117 (68%) were ill. Symptoms included myalgias (93%), headache (87%), and fatigue (79%). The mean incubation period was 49 h and the mean duration of illness was 71 h. Patrons aged >15 years were more likely to have been ill than younger patrons (odds ratio [OR], 2.96; P=.002); 58% of persons who were ill sat near a large fountain, compared with 18% of respondents who were not ill (OR, 7.5; P=.005). Legionella anisa was cultured from water samples obtained from the fountain pool. Of 22 individuals who were ill, 11 (50%) had a > or =4-fold increase in the titer of antibody to that strain of L. anisa from acute-phase to convalescent-phase serum samples; 3 others (14%) had persistently elevated titers of > or =512; of a group of 20 individuals who had not been exposed to the restaurant, none had titers of >128. Pontiac fever should be considered as a diagnosis during acute outbreaks of influenza-like illness with a high attack rate and no other identified etiology.


Assuntos
Surtos de Doenças , Legionella/isolamento & purificação , Doença dos Legionários/epidemiologia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Humanos , Doença dos Legionários/microbiologia , Pessoa de Meia-Idade , Restaurantes , Inquéritos e Questionários , Estados Unidos/epidemiologia , Microbiologia da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...